WebAug 16, 2024 · Aug 16, 2024. #2. If the water pipe counts as an electrode, it must be connected from within 5' of where it enters the structure back to the service equipment. If there's no qualifying water pipe, then you can bond it anywhere. Gas lines are bonded -- per NEC -- by the EGC of the circuit to the equipment that's connected to the gas lines. The grounding electrode system includes all of the grounding electrodes available and the grounding electrode conductor(s). All electrodes used must be bonded together into one common grounding electrode system in accordance with IFGC Section 310.2.3/IRC Section G2411.2.3. A separate grounding … See more The 2024 International Fuel Gas Code (IFGC) and International Residential Code (IRC) have reaffirmed (without any modifications) the … See more Arc-resistant (black) CSST is characterized by a thick black jacket or a multi-layer black jacket system. The single-layer black jacket is designed to absorb arcing energy … See more Existing steel or copper piping systems must be retroactively bonded when modified by adding yellow (non-arc-resistant) CSST to the system regardless of the length of CSST added. A piping system assembled … See more
CSST bonding Electrician Talk
Webd) The bonding conductor [wire] is to be solid or stranded 6 AWG copper [minimum] or equivalent an not to exceed 75 feet in length. The effectiveness of the bond will be improved utilizing the shortest practical conductor [wire] length. e) The bonding conductor [wire] is to be directly and permanently connected to the electrical service ... WebApr 19, 2015 · Bonding/grounding clamps shall be installed in accordance with its listing per UL 467 and shall makemetal-to-metal contact with a rigid pipe component or CSST … philly cheese ball with chip beef
WARDFlex® Corrugated Stainless Steel Tubing (CSST) System
WebJun 18, 2024 · Would appreciate some clarity on CSST bonding- a number of the posts I have read are confusing to me anyway. Is the clamp that is secured to the first csst … WebWhen Direct Bonding is Required by Local Code or Manufacturer's Requirement: a) Yellow jacketed Pro-Flex® CSST must be bonded in accordance with this section. b) The … WebElectrical Bonding of Gastite CSST, in the January 2013 Gastite Design & Installation Guide, based on updates to 2015 NFPA 54 sec. 7.13.2, and 2015 IFGC sec. 310.1.1. … tsa precheck allentown pa